Certifications |
FM (United States, Canada) |
Permitted Use |
ClassT(GAS/VAPOUR), Division 1, Groups C & D |
Maximum Operating Temperature Range (T-Code) |
T4 [ 135゜C ( 275゜F ) ] |
Motor |
Three Phase Squirrel Cage Induction Motor |
Method of Cooling |
Non Jacketed (EMQY) or Jacketed (EMJY) |
Motor Rating HP |
2 POLE (3600RPM) : 2 HP - 40 HP
4 POLE (1800RPM) : 2 HP - 125 HP
6 POLE (1200RPM) : 5 HP - 100 HP
8 POLE ( 900RPM) : 5 HP - 75 HP |
Power Supply |
208, 230, 460, 575V / 60Hz
(Other voltages not more than 600V are available)
(50Hz motors are available by modifying 60Hz motors) |
Insulation |
Class F (155゜C, 310゜F) or Class H (180゜C, 356゜F) |
Service Factor |
1.15 |
Starting Method |
Direct- On-Line or Star-Delta |
Electrical Characteristics |
NEMA Design B |
Lquid Temperature |
40゜C (104゜F)
(Other temperatures are available on request) |
Ambient Air Temperature |
40゜C (104゜F) |
Submersible Depth |
Max. 65 ft (20m) |
Leakage Detector |
Single- or Dual-Electrode Leakage Detectors |
Thermal Protector |
Two Bi-Metallic Thermal Switches |
Cable |
UL approverd specifically designed for submersible applications
chloroprene cable withstands temperatures of up to 90℃(194゜F) |
Materials |
|
Motor Housing
Oil Chamber
Motor Shaft |
ASTM A48, Class 35
ASTM A48, Class 35
AISI 420
|
Shaft Seals |
Double mechanincal seals prevent the water from penetrating into
the oil chamber and the motor housing . |